Configuration and Diagnostics Example

This example will blink the Green LED NUMBER_OF_FLASHES times, CONF_BLINK_EVENTS_PER_DAY times per day and store the total number of flashes in the DIAG_TOTAL_FLASH_COUNT diagnostic field. The number of times the Blinky Job has been called is stored in the DIAG_LAST_SEQUENCE_NUMBER persistent diagnostic field. The CONF_BLINK_EVENTS_PER_DAY configuration field can be updated through the FlexAssist Mobile Application whereas the DIAG_TOTAL_FLASH_COUNT and DIAG_LAST_SEQUENCE_NUMBER can be viewed but not edited from the mobile application. If FlexSense is reset the DIAG_TOTAL_FLASH_COUNT field will be reset while the DIAG_LAST_SEQUENCE_NUMBER field will not.

FlexAssist Mobile Application

The FlexAssist Mobile Application is available on Android and iOS

#include <stdio.h>
#include "flex.h"
#define APPLICATION_NAME "Diagnostics and Configuration Example"
// Green LED ON time
#define LED_ON_TIME_SEC 1
// Green LED OFF time
#define LED_OFF_TIME_SEC 1
// Number of LED Flashes
#define NUMBER_OF_FLASHES 5
// Default Blinky Interval
#define BLINK_EVENTS_PER_DAY 5
// CONF_BLINK_EVENTS_PER_DAY will be set as a configuration type. This type can be viewed and
// updated through FlexAssist and its value will persist even if FlexSense is reset.
#define CONF_BLINK_EVENTS_PER_DAY FLEX_DIAG_CONF_ID_USER_0
// DIAG_TOTAL_FLASH_COUNT will be set as a diagnostic type. This type can be viewed through
// FlexAssist and its value will not persist and will be set to its default if FlexSense is reset.
#define DIAG_TOTAL_FLASH_COUNT FLEX_DIAG_CONF_ID_USER_1
// DIAG_TOTAL_FLASH_COUNT will be set as a persistent diagnostic type. This type can be viewed
// through FlexAssist and its value will persist even if FlexSense is reset.
#define DIAG_LAST_SEQUENCE_NUMBER FLEX_DIAG_CONF_ID_USER_2
// clang-format off
FLEX_DIAG_CONF_TABLE_U32_ADD(CONF_BLINK_EVENTS_PER_DAY, "Blink Events Per Day", BLINK_EVENTS_PER_DAY, FLEX_DIAG_CONF_TYPE_CONF),
FLEX_DIAG_CONF_TABLE_U32_ADD(DIAG_TOTAL_FLASH_COUNT, "Total Flash Count", 0, FLEX_DIAG_CONF_TYPE_DIAG),
FLEX_DIAG_CONF_TABLE_U32_ADD(DIAG_LAST_SEQUENCE_NUMBER, "Last Sequence Number", 0, FLEX_DIAG_CONF_TYPE_PERSIST_DIAG),
// clang-format on
static time_t Blinky(void) {
uint32_t sequence_number = 0;
if (FLEX_DiagConfValueRead(DIAG_LAST_SEQUENCE_NUMBER, &sequence_number) != 0) {
printf("Failed to read the sequence number!\n");
}
uint32_t flash_count = 0;
if (FLEX_DiagConfValueRead(DIAG_TOTAL_FLASH_COUNT, &flash_count) != 0) {
printf("Failed to read the flash count!\n");
}
for (uint8_t i = 0; i < NUMBER_OF_FLASHES; ++i) {
printf("Green LED On\n");
FLEX_Sleep(LED_ON_TIME_SEC);
printf("Green LED Off\n");
FLEX_Sleep(LED_OFF_TIME_SEC);
++flash_count;
}
sequence_number++;
if (FLEX_DiagConfValueWrite(DIAG_LAST_SEQUENCE_NUMBER, &sequence_number) != 0) {
printf("Failed to write the sequence number!\n");
};
if (FLEX_DiagConfValueWrite(DIAG_TOTAL_FLASH_COUNT, &flash_count) != 0) {
printf("Failed to write the flash count!\n");
};
uint32_t blink_events_per_day = BLINK_EVENTS_PER_DAY;
if (FLEX_DiagConfValueRead(CONF_BLINK_EVENTS_PER_DAY, &blink_events_per_day) != 0) {
printf("Failed to read blink_interval_min!\n");
}
return (FLEX_TimeGet() + 24 * 3600 / blink_events_per_day);
}
// Handle the update made to the CONF_BLINK_EVENTS_PER_DAY configuration value.
static void blink_events_per_day_handler(const void *const value) {
if (value == NULL) {
return;
}
const uint32_t *const blink_events_per_day = value;
// Schedule the Blinky job to run at the new interval
FLEX_JobSchedule(Blinky, (FLEX_TimeGet() + 24 * 3600 / *blink_events_per_day));
}
void FLEX_AppInit() {
printf("%s\n", APPLICATION_NAME);
// Creat a handler to run the tracker job if the measurement interval is changed
FLEX_DiagConfValueNotifyHandlerSet(CONF_BLINK_EVENTS_PER_DAY, blink_events_per_day_handler);
// Schedule the Blinky job to run.
}